SetupFrom the pocket register
Behmor 2000AB Plus Automatic vs Manual Mode
Use the Behmor 2000AB Plus presets and Manual Mode. Follow a half-pound example from START through first crack, the attendance prompt, and cooldown.
On the Behmor 2000AB Plus, press the weight button and then START to roast on the default automatic P1 profile. Once the roast is running, press a P1–P5 button to switch to Manual Mode and set heater power. Behmor control-panel guide
What the P buttons do before and after START
| When | What P1–P5 do |
|---|---|
Before START | Select one of five preset heat profiles. Behmor product page · Quick-start guide |
| During the roast | Enter Manual Mode or change its heater setting. The selected button blinks. P1 is 0%, P2 is 25%, P3 is 50%, P4 is 75%, and P5 is 100%. Behmor control-panel guide |
In Manual Mode, press D to toggle between standard and high drum speed. Press the 1 weight button to return to Auto. Behmor recommends P4 and P5 only in the early part of the roast and P1 through P3 for finishing. Behmor control-panel guide
What A, B, and C do during a roast
| Button | In Auto and Manual Mode |
|---|---|
A | Shows exhaust-channel temperature once the exhaust fan starts mid-roast. Behmor control-panel guide |
B | Shows the roasting chamber’s sidewall temperature. Behmor A/B temperature FAQ |
C | Resets the timer to Behmor’s weight-based estimate of the interval from the start of first crack to the start of second crack. Behmor control-panel guide |
Use the A and B readings to follow temperature trends at the sensors. Behmor cautions against using either reading to determine roast level. Behmor A/B temperature FAQ
For regular coffee, Behmor gives approximate first-to-second-crack intervals of 1:30 for a quarter pound, 2:10 for a half pound, and 3:10 for one pound. Behmor quick-start guide
Half-pound example from Auto P1 to cooldown
Use this example once you’re familiar with the roaster. If you’re still learning, Behmor recommends starting with at least four quarter-pound batches on P1. Stay with the roaster whenever it’s in use. Behmor quick-start guide
Attendance prompt in either mode
- When it appears. Behmor bases the
un:30prompt on 75% of the standard default roast time. The safety feature applies in both modes. Behmor control-panel guide - How to continue. If the countdown appears during the sequence below, press
STARTwithin 30 seconds to continue roasting. Behmor Err 7 help - If you miss it. The roaster automatically starts cooling and flashes
Err 7. Behmor control-panel guide
Roast sequence
- With the roaster prepared for a half-pound batch, close the door. Press
1/2, thenSTART, to begin on AutoP1. Behmor control-panel guide - After first crack begins, wait about 10 to 15 seconds. Press
P3→C→Dto switch to Manual at 50% power, reset the timer, and toggle drum speed. Behmor control-panel guide - Press
COOLwhen you’re ready to end the roast. If you see heavy or bluish smoke or hear a heavy rolling second crack, pressCOOLimmediately. Behmor quick-start guide
When a roast needs more time
| Situation | What to do |
|---|---|
| You need more time at first crack | Press + to add time. C resets the timer to the first-to-second-crack estimate for the selected weight. Behmor control-panel guide |
| Roasts take longer in summer | Behmor notes that during high summer electricity demand, lower supply voltage can reduce heater output and lengthen roasts. The maker suggests trying an earlier time of day before electricity demand rises. Behmor on longer roast times |
Evidence and limits
This guide covers the 120 V Behmor 2000AB Plus. Behmor product page
Behmor’s public control-panel guide, quick-start guide, and support notes were checked on November 29, 2026. The example starts with a roaster prepared for use and ends at the start of cooldown. No hands-on testing was performed for this guide.
The farm's pocket register